{"id":45,"date":"2018-10-05T11:58:52","date_gmt":"2018-10-05T09:58:52","guid":{"rendered":"https:\/\/www.guss-magnete.de\/en\/?page_id=45"},"modified":"2019-09-23T14:35:29","modified_gmt":"2019-09-23T12:35:29","slug":"glossary","status":"publish","type":"page","link":"https:\/\/www.guss-magnete.de\/en\/things-to-know\/glossary\/","title":{"rendered":"GLOSSARY"},"content":{"rendered":"<div class=\"row \"><div class=\"wpv-grid grid-1-1  wpv-first-level first unextended\" style=\"padding-top:0px;padding-bottom:0px\" id=\"wpv-column-28345e3ebe1d3e161ac06f33463678f1\" ><h2 style=\"text-align: center;\">GLOSSARY<\/h2><\/div><\/div>\n<div class=\"row \"><div class=\"wpv-grid grid-1-1  wpv-first-level first unextended\" style=\"padding-top:0px;padding-bottom:0px\" id=\"wpv-column-a4c98137b08caa8fec5a79156dce2597\" ><div class=\"row \"><div class=\"wpv-grid grid-1-2  first unextended\" style=\"padding-top:0px;padding-bottom:0px\" id=\"wpv-column-8e8f0ca8a28fc1d5c3286e49faf4f8d5\" ><p><strong>anisotrop<\/strong><\/div>\n<div class=\"wpv-grid grid-1-2  unextended\" style=\"padding-top:0px;padding-bottom:0px\" id=\"wpv-column-2d0dfdece526f1c1670d1566695418eb\" ><p>The magnet has improved magnetic properties running in one direction which is determined by the manufacturing process, the so-called preferred direction.<\/div><\/div>\n<hr \/>\n<div class=\"row \"><div class=\"wpv-grid grid-1-2  first unextended\" style=\"padding-top:0px;padding-bottom:0px\" id=\"wpv-column-440dea4175233f8c448951c9fd03ade6\" ><p><strong>cgs-units<\/strong><\/div>\n<div class=\"wpv-grid grid-1-2  unextended\" style=\"padding-top:0px;padding-bottom:0px\" id=\"wpv-column-dda9b6a104474b69ea43322fbb4a021a\" ><p>physical units which are based on three basic units of centimetres, grams, and seconds,<br \/>\namong others these also include the outdated magnetic units of gauss, maxwell and oerstedt.<\/div><\/div>\n<hr \/>\n<div class=\"row \"><div class=\"wpv-grid grid-1-2  first unextended\" style=\"padding-top:0px;padding-bottom:0px\" id=\"wpv-column-a972ac2d7448ac6d5271db34d6614e7b\" ><p><strong>permanent magnetic assemblies<\/strong><\/div>\n<div class=\"wpv-grid grid-1-2  unextended\" style=\"padding-top:0px;padding-bottom:0px\" id=\"wpv-column-32215699c8f8652d9ea58e06c6b565b1\" ><p>represents a combination of permanent magnetic materials, magnetically soft flux-conducting components and non-magnetic components, usually with the target of bundling the magnetic flux within a defined operating area, e.g. an adherent surface, an annular passage or in free space in trapping systems.<\/div><\/div>\n<hr \/>\n<div class=\"row \"><div class=\"wpv-grid grid-1-2  first unextended\" style=\"padding-top:0px;padding-bottom:0px\" id=\"wpv-column-aedf6798966c23e156f8b7e2f5a5bf2b\" ><p><strong>demagnetization curve<\/strong><\/div>\n<div class=\"wpv-grid grid-1-2  unextended\" style=\"padding-top:0px;padding-bottom:0px\" id=\"wpv-column-bb99d27509a786dc75e10a6547cfdfcb\" ><p>is the course of the hysteresis loop in the second quadrant &#8211; the most important part of the loop, since the operating point of every permanent magnet is located in this part of the loop.<\/div><\/div>\n<hr \/>\n<div class=\"row \"><div class=\"wpv-grid grid-1-2  first unextended\" style=\"padding-top:0px;padding-bottom:0px\" id=\"wpv-column-03c3fc7b6feda1f7553bb743301e10e6\" ><p><strong>hysteresis loop<\/strong><\/div>\n<div class=\"wpv-grid grid-1-2  unextended\" style=\"padding-top:0px;padding-bottom:0px\" id=\"wpv-column-0772c7f702f4ab7df7ae6f8f7c363205\" ><p>the functional connection between the induction B and the magnetization J on the one hand and the magnetic field strength H on the other, B = f(H) bzw. J = f(H).<\/p>\n<p>depending on the width of the hysteresis loop, one can distinguish between magnetically soft, semi-hard and hard materials (the latter is referred to as a permanent magnet)<\/div><\/div>\n<hr \/>\n<div class=\"row \"><div class=\"wpv-grid grid-1-2  first unextended\" style=\"padding-top:0px;padding-bottom:0px\" id=\"wpv-column-67706302cedd2ea1152ea5be0b74959e\" ><p><strong>isotropic<\/strong><\/div>\n<div class=\"wpv-grid grid-1-2  unextended\" style=\"padding-top:0px;padding-bottom:0px\" id=\"wpv-column-f0e9805d3848fb0fab3b7bd9c4973e6d\" ><p>the magnet has the same magnetic properties in all spatial directions, in other words it has no preferred direction<\/div><\/div>\n<hr \/>\n<div class=\"row \"><div class=\"wpv-grid grid-1-2  first unextended\" style=\"padding-top:0px;padding-bottom:0px\" id=\"wpv-column-ce788cb3e5daa0de950c3e2cf3a30dfd\" ><p><strong>\u00a0coercive field strength HcB bzw. HcJ in [kA\/m bzw. Oe]<\/strong><\/div>\n<div class=\"wpv-grid grid-1-2  unextended\" style=\"padding-top:0px;padding-bottom:0px\" id=\"wpv-column-b9cf7712173a9f11323908563a31c001\" ><p>two marked points on the demagnetization curve which are a measure for the resistance of the magnet to demagnetizing external or internal magnetic fields<\/div><\/div>\n<hr \/>\n<div class=\"row \"><div class=\"wpv-grid grid-1-2  first unextended\" style=\"padding-top:0px;padding-bottom:0px\" id=\"wpv-column-72e6ef9d87b6f8e4f922210a4dc01bb2\" ><p><strong>\u00a0magnetic properties Br, (BH)max, HcB und HcJ<\/strong><\/div>\n<div class=\"wpv-grid grid-1-2  unextended\" style=\"padding-top:0px;padding-bottom:0px\" id=\"wpv-column-32f1bbf0f1595892d3e582d5bb82bafc\" ><p>minimum values as determined in-house or by the material standard DIN IEC 60404-8-1 for the remanence Br, the maximum energy product (BH)max as well as the coercive field strength HcB and HcJ<\/div><\/div>\n<hr \/>\n<div class=\"row \"><div class=\"wpv-grid grid-1-2  first unextended\" style=\"padding-top:0px;padding-bottom:0px\" id=\"wpv-column-bd2a3059ca8b0126b370e9158f99b519\" ><p><strong>maximum energy product (BH)max, [kJ\/m\u00b3 bzw. MGOe]<\/strong><\/div>\n<div class=\"wpv-grid grid-1-2  unextended\" style=\"padding-top:0px;padding-bottom:0px\" id=\"wpv-column-28794824076d8033dacc6ec01baa4d64\" ><p>point marked on the demagnetization curve in which the product from B and H is the maximum (largest inscribed rectangle below the curve); in practice the operating point should lie near the (BH)max point in order to achieve the best possible utilization of the given permanent magnetic material<\/div><\/div>\n<hr \/>\n<div class=\"row \"><div class=\"wpv-grid grid-1-2  first unextended\" style=\"padding-top:0px;padding-bottom:0px\" id=\"wpv-column-62ef27199e90cddd7fd10a62f7922846\" ><p><strong>\u00a0Remanenz Br [mT bzw. G]<\/strong><\/div>\n<div class=\"wpv-grid grid-1-2  unextended\" style=\"padding-top:0px;padding-bottom:0px\" id=\"wpv-column-a1f11a7fa127e55d580c5448ac9cdf3b\" ><p>point marked on the demagnetization curve, residual induction in the closed magnetic cycle after switching off the outer magnetizing field strength<\/div><\/div>\n<hr \/>\n<div class=\"row \"><div class=\"wpv-grid grid-1-2  first unextended\" style=\"padding-top:0px;padding-bottom:0px\" id=\"wpv-column-fc5973eba238e6e369cd6b6c27490f92\" ><p><strong>\u00a0SI base unit<\/strong><\/div>\n<div class=\"wpv-grid grid-1-2  unextended\" style=\"padding-top:0px;padding-bottom:0px\" id=\"wpv-column-555455712129bb2328f44431c4444142\" ><p>physical units of measurement from the international system of units based on the units of metre, kilogram, second and ampere<\/div><\/div>\n<hr \/>\n<div class=\"row \"><div class=\"wpv-grid grid-1-2  first unextended\" style=\"padding-top:0px;padding-bottom:0px\" id=\"wpv-column-501c390bcd95bfd199a98caaaaddd6d4\" ><p><strong>\u00a0rod-shaped crystallization<\/strong><\/div>\n<div class=\"wpv-grid grid-1-2  unextended\" style=\"padding-top:0px;padding-bottom:0px\" id=\"wpv-column-5ce2dd4df89031f52896ab47cc8fa13b\" ><p>the crystallization form achieved by applying a targeted release of heat during the casting process, usually long, parallel, pin-shaped crystals<\/div><\/div><\/div><\/div>","protected":false},"excerpt":{"rendered":"<p>GLOSSARY anisotrop The magnet has improved magnetic properties running in one direction which is determined by the manufacturing process, the so-called preferred direction. cgs-units physical units which are based on three basic units of centimetres, grams, and seconds, among others these also include the outdated magnetic units of gauss, maxwell and oerstedt. permanent magnetic assemblies&#8230;<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":37,"menu_order":54,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-45","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/www.guss-magnete.de\/en\/wp-json\/wp\/v2\/pages\/45","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.guss-magnete.de\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.guss-magnete.de\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.guss-magnete.de\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.guss-magnete.de\/en\/wp-json\/wp\/v2\/comments?post=45"}],"version-history":[{"count":9,"href":"https:\/\/www.guss-magnete.de\/en\/wp-json\/wp\/v2\/pages\/45\/revisions"}],"predecessor-version":[{"id":732,"href":"https:\/\/www.guss-magnete.de\/en\/wp-json\/wp\/v2\/pages\/45\/revisions\/732"}],"up":[{"embeddable":true,"href":"https:\/\/www.guss-magnete.de\/en\/wp-json\/wp\/v2\/pages\/37"}],"wp:attachment":[{"href":"https:\/\/www.guss-magnete.de\/en\/wp-json\/wp\/v2\/media?parent=45"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}